NS0-520 | What Refined NS0-520 Exam Is

Want to know Passleader NS0-520 Exam practice test features? Want to lear more about Network-Appliance NetApp Certified Implementation Engineer - SAN. ONTAP certification experience? Study Top Quality Network-Appliance NS0-520 answers to Rebirth NS0-520 questions at Passleader. Gat a success with an absolute guarantee to pass Network-Appliance NS0-520 (NetApp Certified Implementation Engineer - SAN. ONTAP) test on your first attempt.

Free demo questions for Network-Appliance NS0-520 Exam Dumps Below:

NEW QUESTION 1

At which storage object level is deduplication enabled?

  • A. Aggregate
  • B. Volume
  • C. Qtree
  • D. LUN

Answer: B

NEW QUESTION 2

You have finished deploying a Netapp AFF All SAN Array Cluster and want to test the persistent ports feature. In this scenario, how would you accomplish this task?

  • A. Perform a takeover of a node
  • B. Disconnect an FCP initiator port
  • C. Disconnect an FCP target port
  • D. Disable a SAN LIF

Answer: A

Explanation:
If we don't have OnCommand Insight, then we should not pull out a cable as test because it won't be detected properly.
Doing a planned takeover will meet the requirements asked. Table Description automatically generated
NS0-520 dumps exhibit
You can find more information on this link: https://www.netapp.com/pdf.html?item=/media/10379-tr4515.pdf&v=20217121554 (26)

NEW QUESTION 3

Which statement is correct regarding virtual machine alignment on VMware ESX?

  • A. RDM LUNs do NOT suffer from alignment problems because they are accessed directly by VMs.
  • B. A VMFS LUN with a LUN type of VMware, will always have properly aligned VMs.
  • C. Alignment issues can occur on any protocol including FCP, iSCSI, FCoE, and NFS
  • D. msinfo32 or mbrscan can be run for the ESX service console to check for proper alignment of VMs.

Answer: C

NEW QUESTION 4

Exhibit.
NS0-520 dumps exhibit
You are adding a boot LUN for a new server. The server uses FCP attached through a CNA. The ONTAP cluster is also attached to the same fabric by way of UTA2. You configure the zoning for the fabric as shown in the exhibit. You discover that the server cannot see its boot LUN.
What is the problem with your zoning configuration?

  • A. The zone set must have the same name as the zone.
  • B. The zone was not activated.
  • C. The zone used a wrong zone ID.
  • D. The WWPN for the NetApp LIF is incorrect.

Answer: D

NEW QUESTION 5

An administrator is migrating from a third-party's SAN to a newly purchased FAS9000. The administrator decides to use the NetApp Foreign LUN Import (FL1) process.
What must the administrator do for this process to work properly?

  • A. Create multiple igroups for the Initiator ports.
  • B. Create six distinct zones that include specific ports within each zone.
  • C. Zone target ports of source storage with initiator ports of destination storage.
  • D. Make the destination LUN larger than the foreign LUN.

Answer: C

NEW QUESTION 6

You are setting up FC ports and must configure the speeds for both the SAN and the host ports. In this scenario, which statement is correct?

  • A. Set the target port speed higher than the switch port speed.
  • B. Set the target port speed to auto-negotiation.
  • C. Set the target port speed to match the switch port speed.
  • D. Set the target port speed lower than the switch port speed.

Answer: B

NEW QUESTION 7

A company wants to use jumbo frames in their Ethernet network. They should set the packet size to which industry conventional value?

  • A. 1200
  • B. 1500
  • C. 9000
  • D. 12000

Answer: C

NEW QUESTION 8

You are configuring both NVMe and FC on the same AFF A800 2-node ONTAP 9.5 cluster. You are configuring both protocols on the same Cisco FC network switches.
In this scenario, which configuration on the cluster is supported?

  • A. a volume with both LUNs and namespaces
  • B. an SVM with both nvme and fcp allowed protocols
  • C. an AFF A800 node HBA with both NVMe/FC and FC on the same port
  • D. a LIF with both fc-nvme and fcp data protocols

Answer: A

NEW QUESTION 9

Which topology allows for guaranteed maximum network performance for iSCSI?

  • A. isolated VLAN network
  • B. MetroWAN network
  • C. direct connect
  • D. WAN network

Answer: C

NEW QUESTION 10

An administrator is planning a hardware refresh and data migration from a Data ONTAP 7.3 system to new AFF A3-00 cluster that is using ONTAP 9.0. The Mode system only serves FC LUNs to a Windows 2012Rs server cluster that needs to remain connected after migration Referring to the scenario, which method would be used for the LUN migration.

  • A. Unified Host Utility Kit
  • B. 7-Mode Transition Tool (7MIT)
  • C. Foreign LUN import (FLI)
  • D. Oncommand system Manager

Answer: B

NEW QUESTION 11

You are configuring a 4-node AFF A400 ONTAP 9.8 cluster. The data center switches have limited ports, and you are given one 10-Gigabit Ethernet port per node for external access.
In this scenario, which three protocols share the same physical port? (Choose three)

  • A. NVMe/FC
  • B. ISCSI
  • C. FCoE
  • D. Snapmirror
  • E. FC

Answer: BCD

Explanation:
If we have only ethernet switches available, we can only enable protocols over ethernet such as FCoE, ISCSI and Snapmirror.
NVMe/FC and FC need a SAN Fabric switch to work.

NEW QUESTION 12

You are planning to install a new AFF All SAN Array A250 system and want to use persistent ports. In this
scenario, what should be identical within the HA pair?

  • A. FCP port MTU size
  • B. FCP Port
  • C. FCP port names
  • D. FCP port LIF WWNN-based zoning

Answer: C

Explanation:
Graphical user interface, text, application, email Description automatically generated
NS0-520 dumps exhibit
You can find more information on this link: https://www.netapp.com/pdf.html?item=/media/10379-tr4515.pdf&v=20217121554 (11)

NEW QUESTION 13

You have deployed an AFF 400 systems for ISCSI workloads and want to ensure maximum performance to the hosts.
In this scenario, which two steps should be configured? (Choose two)

  • A. Enable Jumbo frames on the network switch
  • B. Enable Jumbo frames on the LIF
  • C. Enable Jumbo frames on the broadcast domain
  • D. Enable Jumbo frames on the IPspace

Answer: AC

Explanation:
Changing the Network port settings at the broadcast domain level will change all ports in that broadcast domain sequentially, or one at the time. This will only cause a disruption if the port is a single point of
failure.
Enable jumbo frames (typically MTU of 9000).All devices in the data path, including initiators, targets, and switches, must support jumbo frames. Otherwise, enabling jumbo frames actually reduces network
performance substantially.
You can find more information on this link: https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/How_to_enable_jum

NEW QUESTION 14

An administrator wants to implement FCoE for connectivity of an AFF A200 using VLAN 3011 for fabric traffic across VSAN 11. When configuring the Nexus switches for FCoE connectivity, which two actions are required? (Choose two.)

  • A. Create a new virtual FC interface and bind the physical interface to it.
  • B. Add the virtual interface to the VSAN.
  • C. Create a port channel and add all of the physical network ports that will have FCoE LIFs.
  • D. Add the adapter MAC address to the network port configuration where the node is connected.

Answer: BC

NEW QUESTION 15

You are provisioning storage to an ESX host that uses iSCSI.
According to NetApp best practice, which three actions accomplish this task? (Choose three.)

  • A. Enable the iSCSI service.
  • B. Bind the iSCSI ports to the software iSCSI adapter.
  • C. Install Virtual Storage Console (VSC) for VMware.
  • D. Enable BGP on the switch.
  • E. Configure MTU 1500 on the switch.

Answer: BCE

NEW QUESTION 16

An administrator has six VMware hosts, each with dual HBAs that are connected to a dual fabric using single initiator multiple target zoning. Four nodes are being added to the existing 4-node ONTAP cluster.
In this scenario, what is the minimum number of FC zones that need to be updated on each fabric switch?

  • A. 6
  • B. 8
  • C. 4
  • D. 2

Answer: B

NEW QUESTION 17

A customer’s NetApp infrastructure is reaching end-of-life (EOL), and they want to inventory their NetApp cluster. The customer wants to make sure that the proposed technical refresh satisfies their growing data demands.
Which two tools would you use to help with this recommendation? (Choose two.)

  • A. Upgrade Advisor
  • B. OneCollect
  • C. Config Advisor
  • D. Active IQ

Answer: AC

NEW QUESTION 18

You have a 100GB volume with the space guarantee set to volume, This volume contains two space reserved 20 GB LUNs. Both LUNs are at 50% use. You then create a snapshot copy of the volume. No
modifications were performed since the snapshot copy was completed, and all actions were performed using the CLI. In this scenario, how much free space does the volume have?

  • A. 60 GB
  • B. 20 GB
  • C. 40 GB
  • D. 80 GB

Answer: A

Explanation:
Both LUN created are inheriting the space reserved parameter from its volume parent, so both LUNs are thick provisioned using 20 GB each one of them and the snapshots have not increased because
there has not been any changes since their creation 100GB - 20 GB - 20GB

NEW QUESTION 19

You have a 4 node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 LUNs that use under 5000 IOPS are moved to a FAS8200 using the lun move command.
In this scenario, what happens to the data after the LUN is moved? (Choose two.)

  • A. The new written data is not compacted.
  • B. The new written data is compacted.
  • C. The existing data is compacted.
  • D. The existing data is not compacted.

Answer: BD

NEW QUESTION 20

You have a 4-node FAS8200 A300 cluster that are using ONTAP 9.3 default settings. For faster performance, you move a volume with LUNs from a node on the FAS8200 to a node on the AFF A300. You determine that your SAN host is still using all active/optimized FC paths to the FAS8300 HA pair.
What do you need to troubleshoot to move all active/optimized FC paths to the AFF A300 HA pair?

  • A. reporting nodes list
  • B. host MPIO and ALUA
  • C. LUN mapping
  • D. igroup WWPNs

Answer: A

NEW QUESTION 21
......

P.S. Certshared now are offering 100% pass ensure NS0-520 dumps! All NS0-520 exam questions have been updated with correct answers: https://www.certshared.com/exam/NS0-520/ (234 New Questions)